KĨ THUẬT CHỤP CẮT LỚP VI TÍNH RUỘT NON KHÔNG XÂM NHẬP TRÊN HỆ THỐNG MÁY ĐA DÃY ĐẦU DÒ TẠI KHOA CHẨN ĐOÁN HÌNH ẢNH BỆNH VIỆN BẠCH MAI

Nguyen Tuan Dung1, Dao Danh Vinh2, Pham Minh Thong2,
1 Bachelor of Engineering, majoring in Diagnostic Imaging Department of College of Medicine, Bach Mai Hospital
2 Department of Diagnostic Imaging, Bach Mai Hospital

Main Article Content

Abstract

SUMMARY
Purpose: To initially assess the technical ability to apply tomography multi - detector row (MDCT) in the small bowel pathology.
Technical subjects and conducting: The group study included 108 patients who were suspected of having the small bowel diseases, admitted to Bach Mai Hospital. The noninvasive protocol was used (non nasojejunal tube). Enteroclysis images were performed by the multi - detector row helical computed tomography system, before and after injection iodinate contrast material, 1.5mm section thickness, multi-planar reformatted.
Results: In group study of 108 patients, MDCT Enterography were well tolerated in 77 patients, 29 patients felt difficultly to perform the protocol because of the large volume of NaCl 0.9%. Two patients had abdominal pain, three patients had nausea, two patient had vomiting at the end of process. MDCT Enterography can diagnose the small bowel tumor, inflammatory small bowel diseases, volvulus of small bowel, duodenal diverticulum.
Conclusion: The MDCT Enterography has good ability for applying and hight value in approaching and detecting the small bowel diseases.

Article Details

References

TÀI LIỆU THAM KHẢO
1. Đào Danh Vĩnh. “Luận văn tốt nghiệp bác sĩ nội trú các bệnh viện”, Hà Nội 2008.
2. Hoàng Đình Âu, Hoàng Đức Kiệt. (2008), “Kết quả bước đầu chụp cắt lớp đa dãy đầu thu kết hợp bơm nước tiểu tràng tại Bệnh viện Hữu Nghị”. Tạp chí y học Việt Nam.
3. Hoàng Sử, Hoàng Kỷ, Vũ Long. (1982), “Chẩn đoán X quang lâm sàng bộ máy tiêu hóa”, NXB Y học.
4. Megitbow J, James S, Elizabeth M et al. Evaluation of bowel distension and bowel wall appearance by using neutral oral constrast agent for multidetector row CT. RSNA 2005, Volume 238; number 1: 87-94.
5. Mourad B, Ameer J, Philippe S et al. Small bowel diseases : Prospective evaluation of Multidetector row
helical CT Enteroclysis in 107 consecutive patients. RSNA 2004; 233: 338-344.
6. Leigthon JA, Sharma VK, Srivathsan K et al. Safety of capsule endoscopy in patients with pancemarker. Gastrointest Endosco 2004; 59: 567-569.
7. Scoutt R. Paulse, BS et al. CT Enterography as a diagnostic tool in evaluating small bowel disorder: Review of clinical experience with over 700 cases. RSNA 2006; 26: 641-662.